{"product_id":"pinza-amperometrica-true-rms-ac-600a-display-ampio","title":"True RMS AC Amperage Clamp Meter 600A 2.4\" Display 9999 Counts","description":"\u003cp style=\"background-color: #f1f5f9; border-radius: 4px; padding: 10px 14px; font-size: 0.95em; line-height: 1.6;\"\u003e📐 AC 10–600 A │ True RMS, 9999 counts │ 30 mm jaw — 🔧 Installation difficulty: 2\/5 │ 🎯 Ideal for: electrical panels, motors and three-phase lines, maintenance of residential and industrial systems\u003c\/p\u003e\u003ch2\u003eAC clamp meter with 9999-count display and 30 mm jaw\u003c\/h2\u003e\u003cp\u003e9999 counts on a 2.4-inch backlit display: the highest resolution in the range, five times that of the 1999 base model, with a 30 mm jaw.\u003c\/p\u003e\u003cp\u003eThe True RMS clamp meter measures AC from 10 to 600 A and, with the test leads, works like a multimeter: AC and DC voltage up to 600 V, resistance, capacitance, frequency and temperature with the included thermocouple.\u003c\/p\u003e\u003ch3\u003eWho chooses it\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eMaintenance workers and electricians who read the display in crowded panels and want decimal places even on high currents.\u003c\/li\u003e\n\n\u003cli\u003eThose measuring loads with inverters, LED drivers or switching power supplies, where True RMS is required.\u003c\/li\u003e\n\n\u003cli\u003eIt is not the right choice for battery and photovoltaic DC, nor for currents below 10 A: in those cases, the AC\/DC version is required.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical analysis and advantages of the True RMS clamp meter\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e🖥️ \u003cstrong\u003e2.4\" backlit 9999-count display:\u003c\/strong\u003e large digits and 0.1 A resolution even at the 600 A range.\u003c\/li\u003e\n\n\u003cli\u003e📊 \u003cstrong\u003eTrue RMS:\u003c\/strong\u003e correct RMS value even with non-linear loads, where an average-value clamp reads a distorted number.\u003c\/li\u003e\n\n\u003cli\u003e📏 \u003cstrong\u003e30 mm jaw:\u003c\/strong\u003e 5 mm wider than the 25 mm base clamp, for thicker conductors.\u003c\/li\u003e\n\n\u003cli\u003e🌡️ \u003cstrong\u003eTemperature from -20 to 1000 °C:\u003c\/strong\u003e with the included thermocouple, check terminals, motors and panel components.\u003c\/li\u003e\n\n\u003cli\u003e🧪 \u003cstrong\u003eCapacitance from 99.9 µF to 9.999 mF:\u003c\/strong\u003e check electrolytic and motor starting capacitors.\u003c\/li\u003e\n\n\u003cli\u003e🛡️ \u003cstrong\u003eCAT III with overvoltage protection:\u003c\/strong\u003e measurement category for distribution panels and fixed circuits.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 16px 0; font-size: 0.95em;\"\u003e\u003ctbody\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eManufacturer\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eAlpha Elettronica\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eType\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eDigital AC clamp meter\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMeasurement principle\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eTrue RMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMeasurement category\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eCAT III\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eAC current\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e10 – 600 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eAC \/ DC voltage\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e10 – 600 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eResistance\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eYes\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eCapacitance\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e99.9 µF – 9.999 mF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eFrequency\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e60 – 1000 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eTemperature\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e-20 – 1000 °C (thermocouple included)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eDisplay\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e2.4\" backlit LCD, 4 digits, maximum reading 9999\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eOther functions\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eData Hold · Automatic shut-off\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMaximum jaw opening\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e30 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eSampling\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eapproximately 3 readings per second\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eProtections\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eOvervoltage\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003ePower supply\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e2 × 1.5 V AAA batteries (not included)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eProtection \/ pollution rating\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eIP20 · II\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eOperating \/ storage temperature\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e0 \/ +40 °C · -10 \/ +50 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eRelative humidity \/ altitude\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e\u0026lt; 80% · up to 2000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMaterial \/ dimensions\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eABS · 195 × 74 × 30 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eSKU \/ EAN\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e98-814 \/ 8017443695382\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background-color: #eff6ff; border-left: 4px solid #2563eb; padding: 14px 16px; margin: 18px 0; border-radius: 0 4px 4px 0; display: flex; align-items: flex-start; gap: 12px;\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/Chi_siamo_oniroview.jpg?v=1751647335\" alt=\"Simone Maccarrone — Oniroview\" width=\"56\" height=\"56\" style=\"width: 56px; height: 56px; border-radius: 50%; object-fit: cover; flex-shrink: 0;\"\u003e\u003cdiv\u003e\n\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 700; color: #1e40af; font-size: 0.95em;\"\u003e💡 Simone's tip — Oniroview\u003c\/p\u003e\n\n\u003cp style=\"margin: 0; line-height: 1.5; font-size: 0.95em; color: #1e293b;\"\u003eThe measurement starts at 10 A: to read a small load, such as a refrigerator or a pump, pass the same conductor through the jaw multiple times and divide the reading by the number of passes. With 5 passes, 3 A becomes 15 A on the display: you enter the range and dividing by 5 gives you the actual value. Always clamp a single conductor, never the cable with phase and neutral together.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003ch3\u003eComplete your project\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e🔗 \u003ca href=\"\/en\/products\/batterie-zinco-carbone-aaa-1-5v-ministilo-super-quality\"\u003eAAA 1.5 V mini-style batteries\u003c\/a\u003e — 2 are required, not included.\u003c\/li\u003e\n\n\u003cli\u003e🔗 \u003ca href=\"\/en\/products\/pinza-amperometrica-ac-dc-600a-true-rms-temperatura\"\u003eAC DC 600A True RMS clamp meter\u003c\/a\u003e — if you also need DC.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between a True RMS clamp meter and a normal one?\u003c\/strong\u003e\u003cbr\u003eA normal clamp calculates the RMS value as if the current were a perfect sine wave. With inverters, LEDs, computers and switching power supplies, the waveform is distorted and the reading deviates from the truth. True RMS measures the actual RMS value, so it remains reliable even on modern systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the minimum current this clamp meter can read?\u003c\/strong\u003e\u003cbr\u003eFor AC, the measurement starts at 10 A and goes up to 600 A. For smaller loads, you can wrap the conductor around the jaw multiple times and divide the reading, or use a multimeter in series. For leakage currents of a few milliamperes, a dedicated clamp is required.\u003c\/p\u003e\u003ch3\u003ePackage contents\u003c\/h3\u003e\u003cp\u003e📦 1× Clamp meter · 1× Case · 1× Pair of red\/black test leads · 1× Thermocouple · 1× User manual\u003c\/p\u003e\u003ch3\u003eWarranty and safety\u003c\/h3\u003e\u003cp\u003e✅ CAT III measurement category · 📜 2-year legal warranty (Legislative Decree 170\/2021) · ⚠️ IP20 rating: indoor and dry environments only. Measurements on live systems must be carried out by qualified personnel, in compliance with the measurement category.\u003c\/p\u003e\u003cp\u003eShipping from Catania. Technical assistance for choosing measuring instruments.\u003c\/p\u003e","brand":"Alpha Elettronica","offers":[{"title":"Default Title","offer_id":56015839887699,"sku":"98-814","price":51.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/pinza-amperometrica-true-rms-ac-600a-display-ampio-01.jpg?v=1795422653","url":"https:\/\/oniroview.com\/en\/products\/pinza-amperometrica-true-rms-ac-600a-display-ampio","provider":"Oniroview","version":"1.0","type":"link"}