{"product_id":"pinza-amperometrica-ac-dc-600a-true-rms-temperatura","title":"AC\/DC Amperometric Clamp Meter 600A True RMS with Thermocouple","description":"\u003cp style=\"background-color: #f1f5f9; border-radius: 4px; padding: 10px 14px; font-size: 0.95em; line-height: 1.6;\"\u003e📐 AC and DC current 600 A │ True RMS │ CAT III — 🔧 Installation difficulty: 2\/5 │ 🎯 Ideal for: photovoltaic systems and energy storage, inverter-driven motors, electrical panels, 12\/24 V systems\u003c\/p\u003e\u003ch2\u003eMeasure AC and DC current up to 600 A without opening the circuit\u003c\/h2\u003e\u003cp\u003eMany clamps only measure AC, but DC measurement is required for photovoltaic systems, batteries, camper vans, and 12\/24 V systems.\u003c\/p\u003e\u003cp\u003eThis AC\/DC clamp meter measures up to 600 A in both cases with a True RMS reading, and also measures voltage up to 600 V, resistance, capacitance, frequency, and temperature with an included thermocouple, as well as the V.F.C. mode for variable frequency drive outputs.\u003c\/p\u003e\u003ch3\u003eWho chooses it\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003ePhotovoltaic and energy storage installers who check the DC current of strings and batteries.\u003c\/li\u003e\n\n\u003cli\u003eElectricians and motor maintenance technicians for inverter-driven motors, thanks to the V.F.C. mode.\u003c\/li\u003e\n\n\u003cli\u003eIt is not the right choice for leakage currents of a few milliamperes: the minimum range is 60 A; a clamp meter dedicated to leakage currents is required.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical analysis and advantages of the AC DC clamp meter\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e⚡ \u003cstrong\u003eAC and DC current up to 600 A:\u003c\/strong\u003e ranges of 60 and 600 A for both currents, without disconnecting anything.\u003c\/li\u003e\n\n\u003cli\u003e📊 \u003cstrong\u003eTrue RMS:\u003c\/strong\u003e correct effective value even with non-linear loads such as inverters, switching power supplies, and LED drivers.\u003c\/li\u003e\n\n\u003cli\u003e🏭 \u003cstrong\u003eV.F.C. mode 200–600 V:\u003c\/strong\u003e stable voltage reading at the output of variable frequency drives for motors.\u003c\/li\u003e\n\n\u003cli\u003e🌡️ \u003cstrong\u003eTemperature from -30 to 1000 °C:\u003c\/strong\u003e with the included thermocouple, check motors, terminals, and panel components.\u003c\/li\u003e\n\n\u003cli\u003e🧪 \u003cstrong\u003eCapacitance from 60 nF to 60 mF:\u003c\/strong\u003e also check start-up and power factor correction capacitors.\u003c\/li\u003e\n\n\u003cli\u003e🔢 \u003cstrong\u003e5999 counts and automatic range selection:\u003c\/strong\u003e reading with decimal places and no need to set the range manually.\u003c\/li\u003e\n\n\u003cli\u003e🔦 \u003cstrong\u003eFlashlight, single-pole voltage tester, and audible signal:\u003c\/strong\u003e work even in dark panels and quickly identify the phase.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 16px 0; font-size: 0.95em;\"\u003e\u003ctbody\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eManufacturer\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eAlpha Elettronica\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eType\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eDigital AC\/DC clamp meter\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMeasurement principle\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eTrue RMS\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMeasurement category\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eCAT III\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eAC current\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e60 A · 600 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eDC current\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e60 A · 600 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eDC voltage\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e600 mV · 6 V · 60 V · 600 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eAC voltage\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e6 V · 60 V · 600 V · 200–600 V (V.F.C.)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eResistance\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e600 Ω – 60 MΩ\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eCapacitance\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e60 nF – 60 mF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eFrequency\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e600 Hz · 1 kHz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eTemperature\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e-30 – 1000 °C (thermocouple included)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eOther functions\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eContinuity · Diode test · Data Hold · Single-pole voltage tester · Flashlight · Automatic range selection\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eDisplay\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e4-digit LCD, maximum reading 5999, audible signal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eSampling\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e3 readings per second\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eProtection\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eOverload\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003ePower supply\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e2 × 1.5 V AAA batteries (not included)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eProtection \/ pollution rating\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eIP20 · 2\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eOperating \/ storage temperature\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e0 \/ +40 °C · -10 \/ +60 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eRelative humidity \/ altitude\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e80% · up to 2000 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eMaterial \/ dimensions\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003eABS · 191 × 70 × 37 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n\n\u003ctd style=\"padding: 8px 12px; font-weight: 600; width: 40%; background-color: #f8fafc;\"\u003eSKU \/ EAN\u003c\/td\u003e\n\n\u003ctd style=\"padding: 8px 12px;\"\u003e98-812 \/ 8017443690981\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cdiv style=\"background-color: #eff6ff; border-left: 4px solid #2563eb; padding: 14px 16px; margin: 18px 0; border-radius: 0 4px 4px 0; display: flex; align-items: flex-start; gap: 12px;\"\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/Chi_siamo_oniroview.jpg?v=1751647335\" alt=\"Simone Maccarrone — Oniroview\" width=\"56\" height=\"56\" style=\"width: 56px; height: 56px; border-radius: 50%; object-fit: cover; flex-shrink: 0;\"\u003e\u003cdiv\u003e\n\n\u003cp style=\"margin: 0 0 4px 0; font-weight: 700; color: #1e40af; font-size: 0.95em;\"\u003e💡 Simone's advice — Oniroview\u003c\/p\u003e\n\n\u003cp style=\"margin: 0; line-height: 1.5; font-size: 0.95em; color: #1e293b;\"\u003eTo get an accurate reading, always clamp around a single conductor: if you close the clamp around a cable with both live and return wires together, the two currents will cancel each other out and you will read almost zero. For DC, keep the cable in the center of the jaws and away from other live conductors, because the DC measurement is affected by nearby magnetic fields. On panels and batteries, the clamp measures the current; use the probes for voltage, up to 600 V.\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\u003ch3\u003eComplete your project\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e🔗 \u003ca href=\"\/en\/products\/batterie-zinco-carbone-aaa-1-5v-ministilo-super-quality\"\u003eAAA 1.5 V mini-style batteries\u003c\/a\u003e — 2 are required, not included.\u003c\/li\u003e\n\n\u003cli\u003e🔗 \u003ca href=\"\/en\/products\/tester-pannelli-fotovoltaici-mppt-800w\"\u003eMPPT 800W photovoltaic panel tester\u003c\/a\u003e — to check the power, open-circuit voltage, and short-circuit current of each panel.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the clamp meter measure DC current?\u003c\/strong\u003e\u003cbr\u003eThis model does, up to 600 A, as well as AC current. Many inexpensive clamps only measure AC because they use a simple current transformer; those that also measure DC use a different sensor, a Hall effect sensor. This is the function required for photovoltaic systems, batteries, and 12\/24 V systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do you measure current with the clamp meter?\u003c\/strong\u003e\u003cbr\u003eSelect AC or DC current, open the jaws and close them around a single conductor, either the live or neutral wire, not the entire cable. The value appears on the display without disconnecting anything. For voltage, resistance, or capacitance, use the included probes, as you would with a multimeter.\u003c\/p\u003e\u003ch3\u003ePackage contents\u003c\/h3\u003e\u003cp\u003e📦 1× Clamp meter · 1× Case · 1× Pair of red\/black probes · 1× Thermocouple · 1× User manual\u003c\/p\u003e\u003ch3\u003eWarranty and safety\u003c\/h3\u003e\u003cp\u003e✅ CAT III measurement category · 📜 2-year legal warranty (Italian Legislative Decree 170\/2021) · ⚠️ IP20 rating: for indoor and dry environments only. Measurements on live systems must be carried out by qualified personnel, in compliance with the measurement category.\u003c\/p\u003e\u003cp\u003eShips from Catania. Technical support for selecting measuring instruments.\u003c\/p\u003e","brand":"Alpha Elettronica","offers":[{"title":"Default Title","offer_id":56015830548819,"sku":"98-812","price":76.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0260\/6222\/5485\/files\/pinza-amperometrica-ac-dc-600a-true-rms-temperatura-01.jpg?v=1795422592","url":"https:\/\/oniroview.com\/en\/products\/pinza-amperometrica-ac-dc-600a-true-rms-temperatura","provider":"Oniroview","version":"1.0","type":"link"}